Page view 9
9
NAME/CODE
DESCRIPTION
CODE/VALUE
A1
Baud Rate
Selects the baud rate for data transmission through the
serial port.
1200
2400 4800
9600
19200
A2
Data Bits and
Parity
Selects the number of data bits and parity of serial
transmission. "8n"=8 data bits with no
parity bit and one stop bit.
"7O"=7 data bits with odd parity bit and one stop bit.
"7E"=7 data bits with even parity bit and one stop bit.
"7n"=7 data bits with no parity bit and two stop bits
8n
7O
7E
7n
A3
Mode of
Serial
Transmission
Selects when data will be sent out of the serial port to a
printer or computer.
"C" = Continuous mode; send data continuously
"d" = Demand mode; send data when a PRINT
command is issued from the printer, computer, or
indicator.
C
d
A4
Display
Check
Actuates the function that illuminates all digit segments,
decimal points, and LCD annunciators in a test
sequence. Pressing the ZERO key to scroll down one
level begins the test sequence.
Press ZERO key
to begin
sequence
A5
Disable the
lb/kg Key
Allows the lb/kg key to be disabled so that an operator
cannot accidentally press the key and change the
display units.
"0" = Disable the lb/kg key "1" = Enable the lb/kg
key
0
1