Floor / Pallet Scale - 8 -
SLP 5: The indicator will enter sleep mode if it is idle for 5 minutes.
SLP 10: The indicator will enter sleep mode if it is idle for 10 minutes.
Press [FUN] to select and [TARE] to move to the next parameter.
4.3 “F3 KEY” FUNCTION SWITCH
Press [FUN] to enter function select. Press [TARE] key to switch among:
Key1: Counting, Gross/Net Weight Display
Key2: Accumulation & Print
Key3: Weight Holding
Key4: Pre-tare Function
Key5: Animal Weighing
4.4 “F4 CHK” CHECKING WEIGHING SETTING
Options: BEEP 1/2/3
4.5 “F5 BRT” BRIGHTNESS
Press [FUN] to change LED brightness. Press [TARE] to switch from 1-8. 8 is the most bright and
most power-consuming.
4.6 “F6 INP” INTERNAL COUNT DISPLAY
Press [FUN] to display the scale internal count.
4.7 “F7 CAL” CALIBRATION
Press [FUN] to enter calibration.
PN: Password. Press [TARE] to change the first digit to be 0, then press [ZERO] to move to the next
digit…in this way enter the password 0000. Then press [FUN] to enter the calibration.
“P1 SP”: Set AD converting speed. Options: 1/2/3/4/5. 1 is the fastest and 5 is the slowest
“P2 AUT”: Set Power-on Zero Range. Options: 0/2/5/10/20/50/100% of the capacity
“P3 RAN”: Set Manual Zero Range. Options: 2/4/10/20/50/100% of the capacity
“P4 AZ”: Set Auto Zero Range. Options: 0.25d/0.5d/1d/2d/4d/Off d=division
“P5 DEC”: Set the decimal points. Options: 0/0.0/0.00/0.000/0.0000
“P6 CAP”: Set Full Capacity.
P7 INC: Set Division Increment. Options: 1/2/5/10/20/50
P8 CAL: Calibration. We recommend complete the set up before calibration. So we skip the details
of calibration here and we will show to how to calibrate in Chapter 5. For now press [TARE] to go to
the next parameter.
P9 INT: Factory Setting. Please do not set this parameter if you are not sure to do so.
P10 RS: Communication Mode. This is for RS232 output setting. Press [FUN] to set up baud rate:
1200/2400/4800/9600/19200 Press [FUN] to confirm and go to print mode selection:
RS PRT: Used for serial printer
RS AUT: Used for transmission after each load
RS COT: Used for continuous transmission to PC or remote display